0

Large Current Battery Short Circuit Test Device

Model Number: BE-XL-10000A/ BE-XL-15000A

Application: Battery Module, Battery Pack, Battery System short circuit.

Short Circuit Mode: Pneumatic drive contact + Vacuum Interrupter

Qty :

INDUSTRY: Other

APPLICATION: Battery Safety Testing

Case Dimension: .

Relevant standards requirement

Test object: battery pack and system
Test conditions:
The test temperature should be at 20±10?or higher. (According to the battery system manufacturer’s request).
All protective devices that affect the function of the test objects and related to the test results shall be in normal operation when the test start.
The main contactors used for charging and discharging should be closed to indicate the feasible vehicle mode and the mode of allowing external charging. If is it not available to be completed in one single test, process two or more tests.
The positive and negative terminals of the test object being connected to each other to create a short circuit. The resistance of the connection (including wiring) which used to create short circuit should not exceeding 5mO.
Keep short circuit until any of the following conditions are met and the test is completed.
The protection function of the test object works and the short circuit current is terminated.
After the temperature of the test object’s shell is stable (the temperature gradient is less than 4?within 2h), the short circuit will continue for at least 1h.
After testing, observe for 2h under the room temperature.