Certification of Test Sieves

"Certified" test sieves are standard production
products, specifically reexamined for assurance to
referenced specifications. The sieve is serialized and
supplied with documentation, traceable to NIST,
detailing the openings and wire diameters of the mesh.
W. S. Tyler uses a View Bazic 8 Image Analyzing Machine
to perform our "Certification" and "Recertification"
services. This state of the art equipment is capable of
measuring to tolerances of less than one micron.
In addition the View Bazic 8 allows W.S. Tyler to
measure considerably more openings and wire diameters
than currently specified by ASTM E-11. The added
measurements and the pattern of examination offer
statistically more valid information.
Top

CPA PARTICLE
ANALYZER

A CPA
can reduce the time and labor costs involved with
traditional sieve analysis. Both the size and shape of
your material is analyzed rapidly and accurately. The
CPA is beneficial both as a stand-alone laboratory unit,
or for in-line process control.
CPA
technology provides the accuracy required to verify
products are within specifications. That means
eliminating the potential for product rejections
altogether. Think about the positive effect that will
have on you bottom line, and the ability to enhance the
quality of the products your company is known for.

CPA
stands for Computerized Particle Analyzer; a new
generation replacement for traditional lab and sieve
equipment. It uses a high resolution CCD (charge coupled
device) camera and sophisticated software developed for
particle size and shape analysis of dry, free-flowing,
non-agglomerating particles in bulk materials. The CPA
analyzes and calculates up to 10,000 particles per
second. The particle size and shape calculations are
performed pixel by pixel, independent of the angle of
the particle. Featuring a real-time function, it can
also be used as a particle counting device. The CPA is
used to successfully analyze many different types of
materials such as pharmaceuticals, food products,
minerals, plastics, abrasives, etc.
|
Correlates to Traditional Sieving Results |
There are no differences in the results between
traditional sieving methods and the CPA |
You will experience fewer product rejections as
a result of the new technology |
|
Analyze both size and shape of your material |
The ability to look at particle geometry as well
as gradation |
Tighter process control ensuring fewer product
rejections |
|
Speed, accuracy, and repeatability |
The ability to accurately perform analyses up to
10X faster than traditional methods |
Increase your efficiency while reducing your
labor costs |
|
Available as a stand-alone laboratory or in-line
plant unit |
Technology available to suit your application
environment |
Effectively analyze your material regardless of
your environmental situation |
|
Custom Engineered In-line Process Control |
Total automation without human intervention |
Unit is engineered to your specifications to
ensure quality materials with fewer product
rejections and less downtime |
|
Compact Size of unit |
Occupies a small amount of space in your lab
environment |
Easily fits into your current lab environment
with few or no modifications |
|
Application Environment |
Laboratory |
Laboratory or In-line |
In-line |
In-line |
|
Minimum Particle Size |
45 microns |
35 microns |
Designed to customer specifications |
Designed to customer specifications |
|
Maximum Particle Size |
Ύ inch |
1-1/2 inchs |
|
|
|
Software Requirements |
Windows 2000, XP |
Windows 2000, XP |
Windows 2000, XP |
Windows 2000, XP |
|
Software is available in English, French,
Spanish, and German |
Top

Gold Series
Test Sieves

Gold
Series
Gold
Series Test Sieves are fabricated using a fine mesh
screen cloth produced to extraordinary "tight"
tolerances. The product assures the user, the
permissible variation of the average openings of the
instrument will be one-half (50%) of the allowable ASTM
or ISO specifications. The Gold Series products are
available in stainless steel frames and cloth, on a
"Special" basis, and sell at premium prices. (USA No. 20
through 500).
-
Made in stainless/stainless construction
-
Designed as "masters" for internal quality assurance
programs.
-
8" diameter
-
Each test Sieve is optically examined, serialized
and supplied with complete traceable documentation
-
Available from USA No. 20 to USA No. 500
-
For more detailed information, please request our
"Product and Price Catalog" from our Information
Center
Top

Jet Series Test
Sieves
Air
Jet Test Sieves
-
Made in stainless/stainless construction
-
Replacement sieves for OEM air jet test sieving
systems
-
200 mm Diameter frame, with rubber seal
-
Overall Height - 1-3/4"
-
Depth to Cloth - 1-1/8"
-
Available from USA No. 8 to No. 635
-
For more detailed informtation, please request our
"Product and Price Catalog" from our Information
Center
Top

Test Sieves USA
Series

All
test sieves conform to the current ASTM E11
specification.
3"
Diameter Test Sieves
-
Made of brass/brass and stainless/stainless
construction
-
Overall Height-Full: 1-3/4"; Half: 1-1/4"
-
Depth to cloth-Full: 1-1/4"; Half: 5/8"
6"
Diameter Test Sieves
-
Made in stainless/stainless construction
-
Overall Height-Full: 2-5/8"; Half: 1-7/8"
-
Depth to cloth-Full: 1-3/4"; Half: 1"
8"
Diameter Test Sieves
-
Made in brass/brass, brass/stainless and
stainless/stainless construction
-
Overall Height-Full: 2-5/8"; Half: 1-5/8"
-
Depth to cloth-Full: 2"; Half: 1"
10"
Diameter Test Sieves
12"
Diameter Test Sieves
-
Made in brass/brass, brass/stainless and
stainless/stainless construction
-
Overall Height-Full: 4-1/4"; Intermediate: 3"; Half:
2-5/8"
-
Depth to cloth-Full: 3-1/4"; Intermediate: 2"; Half:
1-5/8"
18"
Diameter Test Sieves
-
Made in brass/stainless construction
-
Overall Height-Full: 5-1/2"
-
Depth to cloth-Full: 4-1/2"
For
detailed information, including part numbers, sieving
accessories, laboratory services, and test sieve
shakers, please request our "Product and Price Catalog"
from our Information Center.
Test Sieves (Metric)
-
200mm and 300mm diameter metric test sieves
-
Manufactured in brass/stainless or
stainless/stainless construction
-
International Standard Size with metric opening
cloth, made in compliance with ISO 3310-1
specification
-
200mm:
Overall Height
Full: 2-5/8
Half: 1-5/8
Depth to Cloth
Full: 2
Half: 1
-
300mm:
Overall Height
Full: 3
Half: 2
Depth to Cloth
Full: 2-3/8
Half: 1-3/8
For
further information, please contact us or request our
Product and Price catalogue from our Information
Center.
Top

Wet Wash Test
Sieves
-
Brass frame, stainless steel construction
-
Designed for cement and other fine powder
analysis requiring water
-
Standard 8" diamter sieves are availble in 4" and
8" heights
-
3" and 12" designs also available
-
All products are supplied with drain holes in the
lower frame
-
For more detailed information, please request our
"Product and Price Catalog" from our Information
Center
Top
|
| |
|
 |
| |
|