Main Partners |
-
ATP Engg, Netherlands
-
Chem Instruments, U.S.A.
-
Coesfeld, Germany
-
CO.FO.ME.GRA, Italy
-
Defelsko, U.S.A.
-
Delmhorst, U.S.A.
-
Erichsen, Germany
-
Hanatek, U.K.
-
Mastrad, U.K.
-
P.C.W.I., Australia
-
Palmer Wahl, USA
-
RAL, Germany
-
Rhopoint, U.K.
-
T.Q.C., Netherlands
-
Taber, U.S.A.
-
Time Group
|
Other Foreign Partners
-
Brookfield, U.S.A.
-
Cannon, U.S.A.
-
Chlor*rid, U.S.A.
-
DG Colour, U.K.
-
Gardco, U.S.A
-
Kershaw Instrument, U.S.A.
-
Little Joe, U.S.A.
-
Memmert , Germany
-
RAY-RAN Polytest, U.K.
-
Red Devil ,U.S.A.
-
Research Equipment, UK
-
RK Printcoat, U.K.
-
Shaw Moisture Meters, U.K.
-
Thwing Albert, U.S.A.
-
Ueshima, Japan
-
WS Tyler, U.S.A.
-
Zehntner , Switzerland
-
VLM , Germany
|
|
|
Laboratory Instruments for Testing |
|
|
|
|
|
|

|
|
SALT SPRAY CABINETS

SALT SPRAY CABINETS are widely used to test components and
coated panels for corrosion resistance throughout the
automotive, paint, surface coating, chemical, aerospace,
electronic, offshore and defence industries. Salt Spray
Tests and found in various. forms in many National,
lnternational and Corporate Standards, C & W cabinets are
designed to meet and exceed these stringent requirements.
Standard Features include
-
EXTERNAL SALT SOLUTION RESERVOIR 114 litres capacity
supplied on castors with integral filter; sufficient to
allow 10 days continuous Operation. Easy cleaning to prevent
algae growth and easy to fill.
-
HEAVY DUTY PERISTALTIC PUMP with VARIABLE SPEED For accurate
control of salt solution flow to the atomiser, indispensable
for precise collection rates; also eliminates atomiser
blockage
-
ACCURATE FLOWMETER Flush mounted, to monitor salt solution
flow.
-
SOPHISTICATED LUCITE ATOMISER For baffle free mist
generation ensuring precise fall- out readings throughout
the chamber.
-
AIR REGULATOR AND PRESSURE GAUGE To control and monitor the
air pressure required for precise salt fog collection rates.
-
TEMPERATURE CONTROL Micro Processor based with full P.l.D.
control and resin coated Pt 100 temperature sensor allowing
simple keypad settings with accurate digital display.
Temperature Range - Ambient to 55° C. +/-1° C.
-
INTERMITTENT CYCLE TIMERS for salt spray cycle/dry cycle
testing or for pre-set continuous salt spray tests - fully
adjustable salt/dry cycles.
-
HOUR METER Re-settable to record test duration or total
hours run.
-
DRY/MOIST (humid) AIR CONTROL Simple switch-over device for
required setting, depending upon specified Standard
procedure.
-
HUMIDIFIER UNIT Compact internal air saturation unit, fully
protected against overheating and low water. Automatic,
self-filling system.
-
HUMIDIFIER UNIT TEMPERATURE CONTROL Digital display of water
temperature adlustable for different air pressures as
specified in Standards.
-
AIR PURGE SYSTEM Designed to enable the swift evacuation of
salt mist from inside the chamber and to prevent laboratory
contamination when examination of test specimens is
required.
Technical Specification : Model SF
|
Capacity (litres)
|
200 |
450
|
1000
|
2000
|
|
Size External Maximum (mm) L
|
1030 |
1370
|
1960
|
2400
|
|
W |
700 |
930
|
1335
|
1200
|
|
H |
1050 |
1130
|
1410
|
1645
|
|
Size Internal Maximum (mm) L
|
610 |
825
|
1465
|
2000
|
|
W |
510 |
635
|
1040
|
1000
|
|
h1 |
455
|
620
|
720
|
850
|
|
h2 |
660
|
875
|
1065
|
1175
|
|
Sample Racks (20° to vertical)
|
4
|
6
|
8
|
12
|
|
Panel Capacity (150 X 100)
|
76 |
132
|
344
|
516
|
|
Salt Solution (resevoir 114litre 500 x 600 x 550)
|
STD |
STD
|
STD
|
size
on request |
|
Eletric (AMP)
|
13 |
13 |
20
|
30 |
|
Compressed Air |
FLOW
3.5 c.f.m at 15 p.s.i. Pressure 30 to 60 p.s.i. (2 to
4 BAR) Connection 10mm I.D. Plastic Pipe Type Clean,
Dry and Oil Free |
|
Water |
Type
De-Ionised or Mains Water Below 50mg/litre T.D.S
Pressure 30 to 60 p.s.i. (2 to 4 BAR) Connection 10mm
I.D. Plastic Pipe |
|
Drain |
32mm
O.D Plastic Pipe to Liqid Waste. Air Breather / Vent
Pipe Connected to Drain To Atmosphere
|
Top

CCT CABINETS

The cabinets are designed to operate to any one or any
combinabon of the following conditions in any sequence for
any pre-set time.
Salt spray - All Corporate, National and International
Standards.
Humidity - Constant or cyclic temperatures between ambient
and 70 degrees centigrade with 98% Relative humidity.
Dry heat - Dry Heat conditions typically ambient to 70
degrees centigrade.
Air drying - Hot and cold air introduction.
Humidity - Cyclic temperature testing typically 42 - 48 - 42
°C as BS 3900 F2.
Dwell and ramp functions - variable humidity option 10% to
98% Rh, from ambient to 70°C.
Standard Features Include
-
MICROPROCESSOR/CONTROLLER A high specification unit for
control with the capacity to hold up to 20 programs. The
controller is easy to operate with rapid program selection
complete with manual over-ride facility, bar-graph
display, program status display and cycles completed
counter. All programs are protected with security code
access.
-
TEMPERATURE RECORDER Continuous paper type chart recorder
with ON/OFF control for individual test records.
-
FULL VISUAL DISPLAY All events, cycles and test
conditions.
-
KEYLOCK A tamperproof security system to prevent
unauthorised program access.
-
CABINET HUMIDIFIER Internal heated water bath with
automatic level control ensures high Relative Humidity
during the relevant periods of the test cycle.
-
HEAVY DUTY PERISTALTIC PUMP with VARIABLE SPEED For
accurate control of salt solution flow to the atomiser,
indispensable for precise collection rates, also
eliminates atomiser blockage.
-
EXTERNAL SALT SOLUTION RESERVOIR and INTEGRAL FILTER For
easy cleaning and filling.
-
INTERNAL HEAT EXCHANGER To pre-heat the salt solution to
the required temperature before introduction to the
atomiser.
-
ACCURATE FLOWMETER Panel mounted, to monitor salt solution
flow.
-
SOPHISTICATED LUCITE ATOMISER For baffle free mist
generation ensuring precise fall-out readings throughout
the chamber.
-
AIR REGULATOR/PRESSURE GAUGE To control and monitor the
air pressure required for precise salt fog collection
rates.
-
DRY/MOIST (humid) AIR CONTROL A simple switch-over device
for required setting, depending upon specified Salt Spray
Standard procedure. A compact internal air saturation
unit, fully protected against overheating and low water.
Automatic, self-filling system, complete with digital
display of water temperature.
-
AUTOMATIC AIR PURGE Incorporated into test program.
Technical Specifications
| |
SF/200/CCT 200 litres |
SF/450/CCT 450 litres |
SF/1000/CCT 1000 litres |
SF/2000/CCT 2000 litres |
|
Size External Maximum (mm)
|
|
|
|
|
|
L |
1030 |
1370
|
1960
|
2400
|
|
W |
700 |
930 |
1335 |
1200 |
|
H |
1050 |
1130 |
1410 |
164 |
|
Size Internal Maximum (mm) |
|
|
|
|
|
L |
610
|
825
|
1465
|
2000
|
|
W |
510
|
635
|
1040
|
1000
|
|
h1 |
455
|
620
|
720
|
850
|
|
h2 |
660
|
875
|
1065
|
1175
|
|
Services (Water, Air, Power) |
For
full information please ask for technical installation
sheet |
|
Resevoir |
114
litres capacity, standard size (500 x 600 x 550)
castor mounted, with tight fitting lid and integral
filter. Larger sizes available |
Optional Accessories
COMPRESSOR
COMPRESSOR SWITCH
- for automatic switchover to standby or regular air
supply.
DE-IONISER & WATER FILTERS
- recommended for areas with hard water or high
suspended solids.
ENTRY PORTS
- for cable access to monitoring equipment or power
introduction.
SPECIAL RACKING
- to support components/samples in test area as
required.
VARIABLE HUMIDITY -
15%
RH to 98% RH with controlled tempreature.
Top

Humidity Cabinets
High humidity conditions with constant or cyclic
temperatures to meet BS3900F2, ISO 6270, ASTM D2247
|
Cabinet Type |
Humidity Cabinets |
|
Models |
AB5
100 Litre |
AB6
200 Litre |
AB7
450 Litre |
AB8
1000 Litre |
AB9
2000 Litre |
|
Style |
Floor Mounteds |
Floor Mounted |
|
External Dimensions |
L |
1000mm |
1030mm |
1370mm |
1960mm |
2400mm |
|
W |
600mm |
700mm |
930mm |
1335mm |
1200mm |
|
H |
645mm |
1050mm |
1130mm |
1410mm |
1645mm |
|
Internal Dimensions |
I |
600mm |
610mm |
825mm |
1465mm |
2000mm |
|
W |
450mm |
510mm |
635mm |
1040mm |
1000mm |
|
H1 |
375mm |
455mm |
620mm |
720mm |
850mm |
|
H2 |
565mm |
660mm |
875mm |
1065mm |
1175mm |
|
Panel Capicity |
72 |
80 |
132 |
344 |
516 |
|
Power Supply Amp |
13 |
13 |
12 |
20 |
32 |
|
Services |
Power supply: 230V 50/60Hz single phase, other
voltages available on request |
|
Water |
Type: De-ionised or mains water below 50mg/litre TDS
Pressure : 30 to 60 psi (2 to 4 BAR) |
|
Drain |
36mm outside diameter plastic pipe to liquid waste |

HUMIDITY CONDITIONING CABINETS

C & W cabinets are designed to meet the
Environmental testing requirements of the paint,
plastic, packaging, paper, board, electronic,
automotive, aerospace, military, textile and
telecommunications industries.
The units function as variable humidity, temperature
humidity, environmental, climatic or conditioning
cabinets. Temperature and humidity testing and
product conditioning is of vital importance to the
research chemist, development engineer and quality
assurance manager to ensure the product is
researched developed and manufactured to a standard
guaranteed to survive the environment for which it
is designed.
Standard Features include
Digital display of temperature set point via
membrane keyboard
Digital display of humidity level set point via
membrane keyboard
Automatic conditioned air injection
Automatic humidifier level control
Resin coated PT 100 temperature sensor
Capacitive RH. sensor with micro membrane filter
Strong, durable, non-corrodable polyester cabinets
Forced air circulation temperature and humidity
uniformity
Over-temperature alarm protection
Full calibration of temperature and humidity to
N.A.M.A.S. (UKAS)
Technical Specification
|
Models
(HCC/)
|
250NC |
250C |
450NC- |
450C |
1000NC- |
1000C |
|
Exte. Dimensions (mm) L
|
1000
|
1370
|
1980
|
|
w |
700
|
910
|
1310
|
|
H |
940
|
1060
|
1335 |
|
Inte. Dimensions (mm) L
|
600
|
825
|
1430
|
|
W |
500
|
645
|
1000
|
|
H |
637
|
680
|
1060
|
|
Temperature (°C) |
20 to
65 |
|
Accuracy |
+/- 2
All range figures based on laboratory ambient being 20°C
|
|
Humidity
Range %RH |
|
No condenser |
condenser |
No condenser |
condenser |
No condenser |
condenser |
|
50 to 95 |
10 to 95 |
50 to 95 |
10 to 95 |
50 to 95 |
10 to 95 |
|
30 to 95 |
10 to 95 |
30 to 95 |
10 to 95 |
30 to 95 |
10 to 95 |
|
15 to 95 |
10 to 95 |
15 to 95 |
10 to 95 |
15 to 95 |
10 to 95 |
|
|
AT 20°C |
|
AT 30°C |
|
AT 60°C |
|
Electric (AMP)
|
13 |
13 |
20 |
|
Power Rating |
220/240 volts 50/60hz other voltages available on
request |
|
Water |
All
models require a supply of deionised water
|
Top
|
| |
|
 |
| |
|