Laboratory Instruments for Testing

 


 


 

 

 

 

SALT SPRAY CABINETS

 

SALT SPRAY CABINETS are widely used to test components and coated panels for corrosion resistance throughout the automotive, paint, surface coating, chemical, aerospace, electronic, offshore and defence industries. Salt Spray Tests and found in various. forms in many National, lnternational and Corporate Standards, C & W cabinets are designed to meet and exceed these stringent requirements.

 

 

Standard Features include

  • EXTERNAL SALT SOLUTION RESERVOIR 114 litres capacity supplied on castors with integral filter; sufficient to allow 10 days continuous Operation. Easy cleaning to prevent algae growth and easy to fill.

  • HEAVY DUTY PERISTALTIC PUMP with VARIABLE SPEED For accurate control of salt solution flow to the atomiser, indispensable for precise collection rates; also eliminates atomiser blockage

  • ACCURATE FLOWMETER Flush mounted, to monitor salt solution flow.

  • SOPHISTICATED LUCITE ATOMISER For baffle free mist generation ensuring precise fall- out readings throughout the chamber.

  • AIR REGULATOR AND PRESSURE GAUGE To control and monitor the air pressure required for precise salt fog collection rates.

  • TEMPERATURE CONTROL Micro Processor based with full P.l.D. control and resin coated Pt 100 temperature sensor allowing simple keypad settings with accurate digital display. Temperature Range - Ambient to 55° C. +/-1° C.

  • INTERMITTENT CYCLE TIMERS for salt spray cycle/dry cycle testing or for pre-set continuous salt spray tests - fully adjustable salt/dry cycles.

  • HOUR METER Re-settable to record test duration or total hours run.

  • DRY/MOIST (humid) AIR CONTROL Simple switch-over device for required setting, depending upon specified Standard procedure.

  • HUMIDIFIER UNIT Compact internal air saturation unit, fully protected against overheating and low water. Automatic, self-filling system.

  • HUMIDIFIER UNIT TEMPERATURE CONTROL Digital display of water temperature adlustable for different air pressures as specified in Standards.

  • AIR PURGE SYSTEM Designed to enable the swift evacuation of salt mist from inside the chamber and to prevent laboratory contamination when examination of test specimens is required.

Technical Specification : Model SF

Capacity (litres) 200 450 1000 2000
Size External Maximum (mm) L 1030 1370 1960 2400
W 700 930 1335 1200
H 1050 1130 1410 1645
Size Internal Maximum (mm) L 610 825 1465 2000
W 510 635 1040 1000
h1 455 620 720 850
h2 660 875 1065 1175
Sample Racks (20° to vertical) 4 6 8 12
Panel Capacity (150 X 100) 76 132 344 516
Salt Solution (resevoir 114litre 500 x 600 x 550) STD STD STD size on request
Eletric (AMP) 13 13 20 30
Compressed Air FLOW 3.5 c.f.m at 15 p.s.i. Pressure 30 to 60 p.s.i. (2 to 4 BAR) Connection 10mm I.D. Plastic Pipe Type Clean, Dry and Oil Free
Water Type De-Ionised or Mains Water Below 50mg/litre T.D.S Pressure 30 to 60 p.s.i. (2 to 4 BAR) Connection 10mm I.D. Plastic Pipe
Drain 32mm O.D Plastic Pipe to Liqid Waste. Air Breather / Vent Pipe Connected to Drain To Atmosphere

Top

 

CCT CABINETS

The cabinets are designed to operate to any one or any combinabon of the following conditions in any sequence for any pre-set time.

Salt spray - All Corporate, National and International Standards.

Humidity - Constant or cyclic temperatures between ambient and 70 degrees centigrade with 98% Relative humidity.

Dry heat - Dry Heat conditions typically ambient to 70 degrees centigrade.

Air drying - Hot and cold air introduction.

Humidity - Cyclic temperature testing typically 42 - 48 - 42 °C as BS 3900 F2.

Dwell and ramp functions - variable humidity option 10% to 98% Rh, from ambient to 70°C.

Standard Features Include 

  • MICROPROCESSOR/CONTROLLER A high specification unit for control with the capacity to hold up to 20 programs. The controller is easy to operate with rapid program selection complete with manual over-ride facility, bar-graph display, program status display and cycles completed counter. All programs are protected with security code access.
  • TEMPERATURE RECORDER Continuous paper type chart recorder with ON/OFF control for individual test records.
  • FULL VISUAL DISPLAY All events, cycles and test conditions.
  • KEYLOCK A tamperproof security system to prevent unauthorised program access.
  • CABINET HUMIDIFIER Internal heated water bath with automatic level control ensures high Relative Humidity during the relevant periods of the test cycle.
  • HEAVY DUTY PERISTALTIC PUMP with VARIABLE SPEED For accurate control of salt solution flow to the atomiser, indispensable for precise collection rates, also eliminates atomiser blockage.
  • EXTERNAL SALT SOLUTION RESERVOIR and INTEGRAL FILTER For easy cleaning and filling.
  • INTERNAL HEAT EXCHANGER To pre-heat the salt solution to the required temperature before introduction to the atomiser.
  • ACCURATE FLOWMETER Panel mounted, to monitor salt solution flow.
  • SOPHISTICATED LUCITE ATOMISER For baffle free mist generation ensuring precise fall-out readings throughout the chamber.
  • AIR REGULATOR/PRESSURE GAUGE To control and monitor the air pressure required for precise salt fog collection rates.
  • DRY/MOIST (humid) AIR CONTROL A simple switch-over device for required setting, depending upon specified Salt Spray Standard procedure. A compact internal air saturation unit, fully protected against overheating and low water. Automatic, self-filling system, complete with digital display of water temperature.
  • AUTOMATIC AIR PURGE Incorporated into test program.

Technical Specifications

 

  SF/200/CCT 200 litres SF/450/CCT 450 litres SF/1000/CCT 1000 litres SF/2000/CCT 2000 litres
Size External Maximum (mm)        
L 1030 1370 1960 2400
W 700 930 1335 1200
H 1050 1130 1410 164
Size Internal Maximum (mm)        
L 610 825 1465 2000
W 510 635 1040 1000
h1 455 620 720 850
h2 660 875 1065 1175
Services (Water, Air, Power) For full information please ask for technical installation sheet
Resevoir 114 litres capacity, standard size (500 x 600 x 550) castor mounted, with tight fitting lid and integral filter. Larger sizes available

Optional Accessories

  • COMPRESSOR

  • COMPRESSOR SWITCH - for automatic switchover to standby or regular air supply.

  • DE-IONISER & WATER FILTERS - recommended for areas with hard water or high suspended solids.

  • ENTRY PORTS - for cable access to monitoring equipment or power introduction.

  • SPECIAL RACKING - to support components/samples in test area as required.

  • VARIABLE HUMIDITY - 15% RH to 98% RH with controlled tempreature.

Top

 

Humidity Cabinets

High humidity conditions with constant or cyclic temperatures to meet BS3900F2, ISO 6270, ASTM D2247
 

Cabinet Type Humidity Cabinets
Models

AB5
100 Litre

AB6
200 Litre
AB7
450 Litre
AB8
1000 Litre
AB9
2000 Litre
Style

Floor Mounteds

Floor Mounted

External Dimensions L 1000mm 1030mm 1370mm 1960mm 2400mm
W 600mm 700mm 930mm 1335mm 1200mm
H 645mm 1050mm 1130mm 1410mm 1645mm
Internal Dimensions I 600mm 610mm 825mm 1465mm 2000mm
W 450mm 510mm 635mm 1040mm 1000mm
H1 375mm 455mm 620mm 720mm 850mm
H2 565mm 660mm 875mm 1065mm 1175mm
Panel Capicity 72 80 132 344 516
Power Supply Amp 13 13 12 20 32
Services

Power supply: 230V 50/60Hz single phase, other voltages available on request

Water Type: De-ionised or mains water below 50mg/litre TDS
Pressure : 30 to 60 psi (2 to 4 BAR)
Drain 36mm outside diameter plastic pipe to liquid waste

 

HUMIDITY CONDITIONING CABINETS

C & W cabinets are designed to meet the Environmental testing requirements of the paint, plastic, packaging, paper, board, electronic, automotive, aerospace, military, textile and telecommunications industries.

The units function as variable humidity, temperature humidity, environmental, climatic or conditioning cabinets. Temperature and humidity testing and product conditioning is of vital importance to the research chemist, development engineer and quality assurance manager to ensure the product is researched developed and manufactured to a standard guaranteed to survive the environment for which it is designed.

Standard Features include

  • Digital display of temperature set point via membrane keyboard  

  • Digital display of humidity level set point via membrane keyboard

  • Automatic conditioned air injection

  • Automatic humidifier level control

  • Resin coated PT 100 temperature sensor

  • Capacitive RH. sensor with micro membrane filter

  • Strong, durable, non-corrodable polyester cabinets

  • Forced air circulation temperature and humidity uniformity

  • Over-temperature alarm protection

  • Full calibration of temperature and humidity to N.A.M.A.S. (UKAS)

Technical Specification
 

Models (HCC/) 250NC 250C 450NC- 450C 1000NC- 1000C
Exte. Dimensions (mm) L 1000 1370 1980
w 700 910 1310
H 940 1060 1335
Inte. Dimensions (mm) L 600 825 1430
W 500 645 1000
H 637 680 1060
Temperature (°C) 20 to 65
Accuracy +/- 2 All range figures based on laboratory ambient being 20°C
Humidity Range %RH
No condenser condenser No condenser condenser No condenser condenser
50 to 95 10 to 95 50 to 95 10 to 95 50 to 95 10 to 95
30 to 95 10 to 95 30 to 95 10 to 95 30 to 95 10 to 95
15 to 95 10 to 95 15 to 95 10 to 95 15 to 95 10 to 95
AT 20°C
AT 30°C
AT 60°C
Electric (AMP) 13 13 20
Power Rating 220/240 volts 50/60hz other voltages available on request
Water All models require a supply of deionised water

Top

 

 

 

Website designed & maintained by Webz Solutions